ProvenBP software

Reliable BP estimation in complex patients and in challenging conditions

https://provenbp.com © ProvenBP Partnership, 2022

ProvenBP software is designed to accurately estimate BP and heart rate, including in the presence of mechanical interference and cardiac arrhythmias. ProvenBP software uses cuff pressure records obtained during oscillometric upper arm BP measurements as a data source.

ProvenBP software performs automatic validation (reliability assessment) of calculated BP values

ProvenBP software provides the following additional features:

Post-processing of data obtained from oscillometric BP Monitor

Fig. 1. Post-processing of data obtained from oscillometric BP Monitor

To get started with ProvenBP software, you can register and run example calculations at https://service.provenbp.com/.

To use ProvenBP software, it is integrated with medical systems, which include automatic BP monitors.

The effect of the ProvenBP solution for manufacturers of automatic BP monitors and 24-hour BP monitors:

The effect of the ProvenBP solution for telemedicine service providers:

The principles and use of ProvenBP software are described in more detail in the "ProvenBP Software. General Description", as well as in a number of other documents available upon request. The main feature of devices compatible with ProvenBP software is the ability to store a recording of cuff pressure during a BP measurement, and then send this recording through a communication interface. This changes the role of the device in the system. What comes first is not the accurate assessment of BP by the device itself, but its ability to provide high-quality data recording for post-processing. Requirements for devices are described in the document "ProvenBP Software. Compatibility Specifications for BP Monitoring Devices".

The main types of devices that can be data sources for ProvenBP software are:

The following documents describe the practical application of ProvenBP software in medical systems:

Examples of using these solutions are shown below.

An example of a telemedicine system for home BP monitoring

Fig. 2. An example of a telemedicine system for home BP monitoring

An example of a PC-based ABPM system integrated with ProvenBP software

Fig. 3. An example of a PC-based ABPM system integrated with ProvenBP software

For integration, depending on the type of system, you can use several ProvenBP software products. All of them are designed to interact with medical diagnostic systems through the API described in the "ProvenBP Software. Reference Manual" document:

ProvenBP software was designed to provide estimates of central BP and other central hemodynamic parameters equivalent to the SphygmoCor device. This allows the use in medical systems of ready-made clinical reference values for both office and out-of-office conditions, obtained using SphygmoCor devices and a number of compatible devices. They are described in the document "ProvenBP Software. Clinical Reference Values for Central Hemodynamic Parameters".

Medical equipment and systems are subject to mandatory certification. To simplify certification, a package of documents "ProvenBP Design History File" is supplied with ProvenBP software. It contains preparatory materials for compiling a technical file for a medical device in accordance with the requirements of the main markets.

* * *

ProvenBP technology is designed to remove economic and technological barriers to integrating pulse wave analysis (PWA) techniques into mass produced BP monitoring devices and systems.

There are already necessary conditions for this: